Fireray beam detector installation manual

For detectors approved to ul268 refer to nfpa72 for installation guidance. Up to 2 detector heads can report to a single ground level controller. This can be either on the vertical or horizontal axis. Installation instructions linear smoke detector fireray 50100rv stpmfzab 610f. Position beam as high as possible, but with a minimum distance of 0.

Fireray 5000 installation video uk english youtube. Analysis of the modulated infrared beam by the control unit determines whether smoke is present, and if so generates an alarm signal. Edwards signaling manufacturers a complete line of audible and visual signals for industrial and commercial applications. The fireray 50r100r series of reflective infrared optical beam smoke detectors are comprised of a single unit incorporating an infrared transmitter and receiver.

Fireray 3000 installation video uk english duration. This option allows the installer to optimise beam alignment, either manually or. General this document details the routine servicing and maintenance procedures and provides a fault finding guide for the fireray 2000 optical beam smoke detector. The beam detector heads shall include an integral builtin laser pointer to assist prism mounting. A modulated infrared beam from transmitter to receiver is analysed by the control box to determine whether smoke is present. It provides autoalignment for fast and easy alignment, and a lowlevel controller for easy maintenance without need for access. It provides autoalignment for fast and easy alignment, and a lowlevel controller. Fireray fr50rv fr100rv beam smoke detector installation manual. Jul 16, 2015 fireray 5000 is a beam detector for smoke detection in open areas. Fireray5000ul beam smoke, reflective reflective linear smoke detector with one detector head and one prism, range min.

The fireray 5000 motorised reflective, auto aligning infrared optical beam smoke detector can be installed with up to two detector heads per system, thus. The fireray 5000 is the first of a new family of auto aligning infrared optical beam smoke detector products and accessories. Manual or automatic reset system description fireray 2000 comprises a transmitter, which projects a modulated infrared light beam to a receiver. D usually, the detector and the reflector are installed at the same height and oriented. Fireray 2000 installation guide global fire control, inc. Jul 16, 2015 ffe ltd manufacturer of fireray and talentum 2,511 views 6. If the roof is considered to have an apex, place thefirebeam system 0. Table of contents bosch security and safety systems. The fireray 2000 optical beam smoke detector is an active infrared smoke detector. Fireray 5000 beam detector installation manual february 2, 2019 by arfan leave a comment installation missioning and operator hand fireray 100r 330 foot reflective beam detector c tec trade fireray accessories sheet k85001 0616 ec5000r reflective beam detector. The fireray 5000 motorised reflective, auto aligning infrared optical beam smoke detector can be installed with up to two detector heads per system, thus saving on installation time and costs. See detector install guide for more details 004400304 user guide. Fireray 5000 reflective motorized autoalign beam smoke det. This manual is available online at general description system sensor model beam1224beam1224s is a long range projected beam smoke detector designed to provide open area protection.

Fireray 5000 beam detector installation manual new images beam. Edwards signaling ec50r 100r reflective beam smoke detector. Ffe ltd manufacturer of fireray and talentum 4,905 views. The new simplex addressable beam detector combines the power and flexibility of idnet technology with the proven performance of the fireray 5000 optical beam smoke detector. Once the detector head is installed, using the easy. Installation, commissioning and operator handbook products. One minute autoalignment just steer the laser onto the reflector.

Product information linear smoke detector fireray 50100rv pi 34. Beam detectors are used to provide open area smoke detection in situations where it is either impractical or not cost effective to use traditional pointtype. Using the fireray one, it couldnt be easier to bring the benefits of beam detection to your application. Fireray 3000 installation video uk english youtube. Reflective optical beam smoke detector user guide 1. The recommended installation height is between 30 60cms below the ceiling. In addition, each system controller houses two pairs of. The fireray 5000 system is an autoaligning, selfcorrecting infrared beam smoke detector. G 297058 to en54 part 12 fireray 2000 installation guide 22318. Do not install the detector or reflector in environments where condensation or icing are likely to occur for ranges between 5m and 50m, use a 50m detector with 1 reflector. Fireray fr50rv fr100rv beam smoke detector installation. Generalinformation 30cm 30cm transmitter receiver power supplyunit controller 5120m.

For installation of 818m, please use the enclosed short range mask. Page 1 selectable alarm thresholds low current consumption ground level electronics manual or automatic reset automatic contamination compensation fire fighting enterprises ltd. The reflective beam type smoke detector shall be a ffe ltd 5000. If smoke is present in the beam path for more than approx. The signal is reflected by a prism and analysed for smoke presence. Fireray 3000 beam detector, 5 120 m fireray series. For installations complying with ul268nfpa72, the maximum. Beam1224, beam1224s singleended reflected type projected. The detector installs to the building fabric between 0. This innovative system has been designed from the ground up to include pioneering technology that fully. Watch this video to understand the steps needed to install and align the 50100r reflective beam smoke detector.

With no specialist tools or knowledge needed for installation and operation, the fireray one is a standalone beam detector that prioritises ease of installation. Fireray 3000 exd flameproof optical beam smoke detector the fireray 3000 exd is ideally suited for the protection of large areas, with potentially explosive atmospheres, against smoking fires. Fireray 50100r installation video ffe ltd manufacturer of fireray. Fireray 3000 exd comprises an infrared transmitter and a receiver, both of which are atexcertified for use in class 1 div 1 group 2 hazardous areas. This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user, both now and in the future. Fireray 50r100r installation recommendations the installation of the ray infrared optical beam smoke detector should be undertaken in accordance with recognized.

Autoaligns using the integrated user interface just steer the laser onto the reflector, then at the flick. Page 3 detector positioning it is important that the fireray 2000 detector is positioned correctly to minimise the detection time. Mounting tips usually, the detector and the reflector are installed at the same height and oriented towards each other. The received signal is analysed by a controller usually located at ground level. Fireray 5000 is a beam detector for smoke detection in open areas. Zettler fireray 2000 optical beam smoke detector legacy. Fireray 2000 comprises of a transmitter which projects a modulated infrared light beam onto a. The fireray 3000 end to end infrared optical beam smoke detector obsd has been designed using the latest optical technology, incorporating modern industrial, electronic and software techniques. Experiments have shown that smoke from a fire does. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. Using the fireray one, it couldnt be easier to bring the benefi ts of beam detection to your application. The transmitter emits an invisible infrared light beam that is reflected via a prisms mounted directly opposite and with a clear line of sight.

D the detector must be installed such that sunlight and artificial light do not beam directly into the. The projected beam type smoke detector shall be a 4wire 24 vdc device to be used with a separately supplied 4wire control panel. Fireray 2000 eexd hazardous area smoke detector installation guide page 1 of 12 key features flameproof receiver and transmitter standard fireray controller unit high coverage up to 15002m per system low cost beam range 10 metres to 100 metres 12 volts dc to 24 volts dc operation selectable alarm thresholds low current consumption. Installation manual planning notes for automatic fire detectors type. It requires a little as 15cm diameter clearance for the beam path. Smoke detection potter electric signal company, llc. The relatively broad angle of the ir beam eases adjustment and guarantees reliable longterm stability. However in all installations the national fire standards for that particular country must be consulted. Please thoroughly read this manual and applicable sections of system sensors singleended reflected beam detector application guide bmag240.

The installation of the fireray 3000 infrared optical beam smoke detector should be undertaken in accordance with the recognised national,or. Fireray 5000 beam detector installation manual new. Fire alarm systems fireray5000ul beam smoke, reflective fireray5000ul beam smoke, reflective. The projected beam type smoke detector shall be a 4wire 24vdc device. It is also very suited to applications where access to ceiling mounted smoke detectors presents. Fireray 50ru100ru accessories the fireray 50100ru system is a reflective beam smoke detector, which comprises of a single unit incorporating an infrared transmitter and receiver. Product description the fireray 50100rv is a linear optical black and white smoke detector. Fireray fireray approvals worldwide approvals include en54.

One personal installation all of the internal and external features of the fireray one ensure that anyone can align the beam detector perfectly, because the experience and expert knowledge of beam detection has been engineered into the product. For ranges between 50m and 100m, use a 100m detector. Extended monitoring area transmitter, receiver, and evaluating unit integrated into a compact housing electronic help for detector alignment and automatic detector calibration procedure automatic compensation for contamination led display in control unit for various operating states adjustable alarm thresholds. Fireray 3000 is an endtoend beam smoke detector providing smoke detection to open areas with obstructed ceiling. Analysis of the modulated infrared beam by the control unit determines whether smoke is present, and if so generates an alarm.

Esp firebeam installation manual page 9 of 19 2011 hochiki europe uk ltd 23040iss2dec11 receiver sensitivity starts off at 5% and output power starts at 10%. Fireray one autoaligning beam detector potter electric. This innovative system has been designed from the ground. The system is designed to be mounted so that the beam will project between 0. In addition, each system controller houses two pairs of fire and fault relays, one per detector. Fireray installation accessories fireray 3000 smoke detection endtoend infrared optical beam smoke detector. Installation and maintenance instructions beam1224, beam1224s singleended reflected type projected beam smoke detector 3825 ohio avenue, st. Peel off the white backing cover to reveal adhesive surface and place squarely on to the standard 10cm x 10cm reflector.

The beam will start by raising its sensitivity first and can rise all the way up to 100%, after this the output power will rise. Endto end optical beam smoke detector user guide en. The temperature range of the system shall be 4f to 1f 20c to 55c. The system comprises a transmitter which projects a modulated infrared beam over an area to a receiver, which then forwards a signal to a control unit for analysis. Ffe is a global innovator in the design and the manufacture of world class fire detection solutions. Fireray test and acceptance of the system shall be carried out by using the ululcfm approved internal electronic obscuration fire test. It provides autoalignment for fast and easy alignment, and a lowlevel. The system comprises a transmitter, a receiver, and a control box. Sep 22, 2016 bosch power tools ds240 users manual hochiki europe uk ltd spc manualzz sheet e85001 0560 reflective beam detector using the mounting bracke fireray 50r 100r ffe beam detectors installation instructions. Reflective optical beam smoke detector user guide safelincs. Fireray 3000 exd potter electric signal company, llc.